|
Basic Characteristics of Mutations
|
|
Mutation Site
|
A264D |
|
Mutation Site Sentence
|
Methods: A mediator probe polymerase chain reaction (PCR) assay was developed to detect the BA.2.86 lineage in wastewater by targeting a specific mutation (Spike: A264D). |
|
Mutation Level
|
Amino acid level |
|
Mutation Type
|
Nonsynonymous substitution |
|
Gene/Protein/Region
|
S |
|
Standardized Encoding Gene
|
S
|
|
Genotype/Subtype
|
BA.2.86 |
|
Viral Reference
|
-
|
|
Functional Impact and Mechanisms
|
|
Disease
|
-
|
|
Immune
|
- |
|
Target Gene
|
-
|
|
Clinical and Epidemiological Correlations
|
|
Clinical Information
|
- |
|
Treatment
|
- |
|
Location
|
- |
|
Literature Information
|
|
PMID
|
38736992
|
|
Title
|
Early Detection of the Emerging SARS-CoV-2 BA.2.86 Lineage Through Wastewater Surveillance Using a Mediator Probe PCR Assay - Shenzhen City, Guangdong Province, China, 2023
|
|
Author
|
Du C,Peng Y,Lyu Z,Yue Z,Fu Y,Yao X,Tang J,Luo G,Gao C,Fang S,Shi X,Wan C,Li Y,Hu Q
|
|
Journal
|
China CDC weekly
|
|
Journal Info
|
2024 Apr 12;6(15):332-338
|
|
Abstract
|
INTRODUCTION: The emergence of the new severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Omicron sublineage, BA.2.86, has sparked global public health concerns for its potential heightened transmissibility and immune evasion. Utilizing data from Shenzhen's city-wide wastewater surveillance system, we highlight the presence of the BA.2.86 lineage in Shenzhen. METHODS: A mediator probe polymerase chain reaction (PCR) assay was developed to detect the BA.2.86 lineage in wastewater by targeting a specific mutation (Spike: A264D). Between September 19 and December 10, 2023, 781 wastewater samples from 38 wastewater treatment plants (WWTPs) and 9 pump stations in ten districts of Shenzhen were examined. Through multiple short-amplicon sequencing, three positive samples were identified. RESULTS: The BA.2.86 lineage was identified in the wastewater of Futian and Nanshan districts in Shenzhen on December 2, 2023. From December 2 to 10, a total of 21 BA.2.86-positive wastewater samples were found across 6 districts (Futian, Nanshan, Longhua, Baoan, Longgang, and Luohu) in Shenzhen. The weighted average viral load of the BA.2.86 lineage in Shenzhen's wastewater was 43.5 copies/L on December 2, increased to 219.8 copies/L on December 4, and then decreased to approximately 100 copies/L on December 6, 8, and 10. CONCLUSIONS: The mediator probe PCR assay, designed for swift detection of low viral concentrations of the BA.2.86 lineage in wastewater samples, shows promise for detecting different SARS-CoV-2 variants. Wastewater surveillance could serve as an early detection system for promptly identifying specific SARS-CoV-2 variants as they emerge.
|
|
Sequence Data
|
-
|
|
|