Basic Characteristics of Mutations
|
|
Mutation Site
|
Y181C |
|
Mutation Site Sentence
|
DESIGN: OLA-Simple probes to detect K65R, K103N/S, Y181C, M184V, and G190A were optimized for HIV Mexican sequences. |
|
Mutation Level
|
Amino acid level |
|
Mutation Type
|
Nonsynonymous substitution |
|
Gene/Protein/Region
|
RT |
|
Standardized Encoding Gene
|
gag-pol:155348
|
|
Genotype/Subtype
|
HIV-1 B |
|
Viral Reference
|
-
|
|
Functional Impact and Mechanisms
|
|
Disease
|
HIV Infections
|
|
Immune
|
- |
|
Target Gene
|
-
|
|
Clinical and Epidemiological Correlations
|
|
Clinical Information
|
- |
|
Treatment
|
NNRTIs |
|
Location
|
Mexico |
|
Literature Information
|
|
PMID
|
32205723
|
|
Title
|
Near point-of-care, point-mutation test to detect drug resistance in HIV-1: a validation study in a Mexican cohort
|
|
Author
|
Panpradist N,Beck IA,Ruth PS,Avila-Rios S,Garcia-Morales C,Soto-Nava M,Tapia-Trejo D,Matias-Florentino M,Paz-Juarez HE,Del Arenal-Sanchez S,Reyes-Teran G,Lutz BR,Frenkel LM
|
|
Journal
|
AIDS (London, England)
|
|
Journal Info
|
2020 Jul 15;34(9):1331-1338
|
|
Abstract
|
OBJECTIVE: Pretreatment HIV-drug resistance (PDR, HIVDR) to non-nucleoside reverse transcriptase inhibitors (NNRTIs) is increasing globally. NNRTIs continue to be used as first-line antiretroviral therapy (ART) in some communities due to the cost of dolutegravir-based ART or dolutegravir-associated adverse events. A simplified version of the oligonucleotide ligation assay (OLA) - 'OLA-Simple' - is a low-cost, near point-of-care assay that provides ready-to-use lyophilized reagents and reports HIVDR mutations as colored lines on lateral flow strips. Our objective was to design and validate OLA-Simple for a Mexican cohort. DESIGN: OLA-Simple probes to detect K65R, K103N/S, Y181C, M184V, and G190A were optimized for HIV Mexican sequences. Sixty clinical plasma specimens were analyzed by OLA-Simple by technicians blinded to Illumina-MiSeq sequences, and HIVDR results were compared. METHODS: Plasma RNA was tested using OLA-Simple kits. OLA-Simple lateral flow strips were read by in-house software, and were classified as mutant or wild-type at each codon. The comparison of results by OLA-Simple and Miseq was used to generate receiver-operating characteristic curves. RESULTS: OLA-Simple PCR amplified 59 of 60 specimens and successfully genotyped 287 of 295 codons, with eight of 295 (2.7%) indeterminate results. Compared to MiSeq, OLA-Simple gave five of 295 (1.7%) false-positive and four of 295 (1.4%) false-negative results. Excluding indeterminate results, OLA-Simple classified mutant with an accuracy of 97.4 and 98.8% when using thresholds at 10 and 25% mutant within an individual's HIV quasispecies, respectively. CONCLUSIONS: Compared to MiSeq, OLA-Simple detected HIVDR with high sensitivity and accuracy. OLA-Simple could expand access to affordable and rapid HIVDR testing to guide appropriate ART choices in populations using NNRTI-based ART.
|
|
Sequence Data
|
MT044195-MT044237;MT070765-MT070781.
|
|
|